01Liquid & chemistry
Liquid composition, concentration, additives and cleaning chemicals.
Hydrophilic membrane filtration for aqueous process liquids. Match the membrane grade, cartridge dimensions and sealing configuration to your filtration task.
A membrane surface, an extended pleated area and a cartridge configuration selected together.
Explore the filtration layer, supporting structure and connections that work together inside the housing.
The thin pleated membrane provides the filtration layer. Its selected grade defines the intended retention performance.

Review the membrane, installation dimensions and operating limits as one complete configuration.
| Filter medium | Polyethersulfone (PES) membrane |
|---|---|
| Wetting characteristic | Hydrophilic |
| Construction | Pleated membrane with support and drainage layers |
| Grade selection | Select the pore-size designation together with its retention efficiency and test basis |
| Nominal lengths | 5, 10, 20, 30 and 40 inches |
|---|---|
| Outside / inside diameter | 68 mm / 33 mm reference format |
| End connections | Double open end (DOE), 222 and 226 adapters |
| Seal options | Silicone, EPDM, NBR, FKM and PTFE-encapsulated |
| Core & end caps | Polypropylene reference construction |
| Normal operating temperature | ≤60°C |
|---|---|
| Maximum operating temperature | 80°C |
| Maximum differential pressure | 4 bar at 21°C; 2.4 bar at 80°C |
| Recommended change-out differential pressure | 1.5–2.0 bar |
| Configuration basis | Reference membrane cartridge format; select the complete wetted construction around the process liquid |
Compare membrane grades under the same reference conditions. Read flow and differential pressure together.
Differential pressure (bar)
| Flow rate (L/min) | Differential pressure (bar) |
|---|---|
| 0 | 0 |
| 5 | 0.083 |
| 10 | 0.17 |
| 15 | 0.263 |
| 20 | 0.36 |
| 25 | 0.463 |
| 30 | 0.57 |
| Flow rate (L/min) | Differential pressure (bar) |
|---|---|
| 0 | 0 |
| 5 | 0.052 |
| 10 | 0.107 |
| 15 | 0.166 |
| 20 | 0.228 |
| 25 | 0.294 |
| 30 | 0.363 |
| Flow rate (L/min) | Differential pressure (bar) |
|---|---|
| 0 | 0 |
| 5 | 0.029 |
| 10 | 0.06 |
| 15 | 0.094 |
| 20 | 0.13 |
| 25 | 0.169 |
| 30 | 0.21 |
Match the cartridge to the seating, sealing and overall dimensions of your housing.
Identify the total installed length L, outside diameter D and bore diameter d. Include the adapter when comparing overall dimensions.
Four details connect the filtration task with a useful cartridge specification.
Liquid composition, concentration, additives and cleaning chemicals.
Particles to remove, required liquid quality and downstream requirements.
Required flow, temperature, available pressure and batch or continuous operation.
Current cartridge photographs, dimensions, connections or a drawing.
Aqueous filtration tasks where membrane selection, liquid quality and housing fit matter.

Tell us what you are filtering, what needs removing and how the cartridge fits into your process. We can work through the membrane grade, dimensions and sealing configuration together.
Discuss this productPES Pleated Filter Cartridges