PES Pleated Filter Cartridges.

Hydrophilic membrane filtration for aqueous process liquids. Match the membrane grade, cartridge dimensions and sealing configuration to your filtration task.

Filter medium
Hydrophilic PES membrane
Construction
Pleated membrane
Length options
5 / 10 / 20 / 30 / 40 in
End connections
DOE / 222 / 226
Discuss this product

PES Membrane Features

A membrane surface, an extended pleated area and a cartridge configuration selected together.

White caged pleated membrane cartridges with double O-ring adapters on a neutral studio background
A membrane for aqueous liquids.
A hydrophilic PES membrane allows water-based liquids to wet the filtration surface and pass through the membrane.
More surface within the cartridge.
Pleating fits an extended membrane surface into a compact cylindrical format.
Fit beyond the membrane.
End connections, seals and cartridge dimensions complete the match between the filter and your housing.

Cartridge Construction

Explore the filtration layer, supporting structure and connections that work together inside the housing.

The filtration layer

The thin pleated membrane provides the filtration layer. Its selected grade defines the intended retention performance.

Cutaway of a caged membrane cartridge revealing thin pleated sheets, support mesh and a perforated core
Explore the layers. Select a component to see its role.

Specifications

Review the membrane, installation dimensions and operating limits as one complete configuration.

Media & filtration

Media & filtration
Filter mediumPolyethersulfone (PES) membrane
Wetting characteristicHydrophilic
ConstructionPleated membrane with support and drainage layers
Grade selectionSelect the pore-size designation together with its retention efficiency and test basis

Dimensions & configuration

Dimensions & configuration
Nominal lengths5, 10, 20, 30 and 40 inches
Outside / inside diameter68 mm / 33 mm reference format
End connectionsDouble open end (DOE), 222 and 226 adapters
Seal optionsSilicone, EPDM, NBR, FKM and PTFE-encapsulated
Core & end capsPolypropylene reference construction

Operating conditions

Operating conditions
Normal operating temperature≤60°C
Maximum operating temperature80°C
Maximum differential pressure4 bar at 21°C; 2.4 bar at 80°C
Recommended change-out differential pressure1.5–2.0 bar
Configuration basisReference membrane cartridge format; select the complete wetted construction around the process liquid

Flow & Differential Pressure Curves

Compare membrane grades under the same reference conditions. Read flow and differential pressure together.

Flow & differential pressure

Differential pressure (bar)

Flow and differential pressure comparisonIllustrative data, not measured product performance. Flow rate (L/min) on the horizontal axis; Differential pressure (bar) on the vertical axis. Curves: 0.1 μm, 0.22 μm, 0.45 μm. Exact input values are available in the data table below.00.150.30.450.60612182430Flow rate (L/min)
Illustrative comparison · not measured product data
View curve data
0.1 μm
Flow rate (L/min)Differential pressure (bar)
00
50.083
100.17
150.263
200.36
250.463
300.57
0.22 μm
Flow rate (L/min)Differential pressure (bar)
00
50.052
100.107
150.166
200.228
250.294
300.363
0.45 μm
Flow rate (L/min)Differential pressure (bar)
00
50.029
100.06
150.094
200.13
250.169
300.21

Dimensions & End Connections

Match the cartridge to the seating, sealing and overall dimensions of your housing.

LDdSIDE ELEVATIONEND VIEW

Identify the total installed length L, outside diameter D and bore diameter d. Include the adapter when comparing overall dimensions.

Selection Guide

Four details connect the filtration task with a useful cartridge specification.

01Liquid & chemistry

Liquid composition, concentration, additives and cleaning chemicals.

What it informsMembrane, support & seal materials

02Filtration objective

Particles to remove, required liquid quality and downstream requirements.

What it informsMembrane grade & retention basis

03Process conditions

Required flow, temperature, available pressure and batch or continuous operation.

What it informsCartridge length, quantity & operating fit

04Housing & installation

Current cartridge photographs, dimensions, connections or a drawing.

What it informsDimensions, end caps & seals

Applications

Aqueous filtration tasks where membrane selection, liquid quality and housing fit matter.

Frequently Asked Questions

A technician concentrating on a precision task in natural light

Your liquid. A clearer specification.

Tell us what you are filtering, what needs removing and how the cartridge fits into your process. We can work through the membrane grade, dimensions and sealing configuration together.

Discuss this product

PES Pleated Filter Cartridges

  • Liquid & composition
  • Filtration objective
  • Flow & temperature
  • Housing & dimensions
PES Pleated Filter Cartridges | Filtrune